Fanuc Alarm 453 n AXIS : SPC SOFT DISCONNECT ALARM
Fanuc Servo Alarm Description
Software disconnection alarm of the α pulse coder. Turn off the power to the CNC, then remove and insert the pulse coder cable. If this alarm is issued again, replace the pulse coder.