Fanuc Alarm 46 ILLEGAL REFERENCE RETURN COMMAND


Fanuc Alarm 46 ILLEGAL REFERENCE RETURN COMMAND

Fanuc Alarm Description
Other than P2, P3 and P4 are commanded for 2nd, 3rd and 4th reference position return command.

30i, 31i, 32i Model A
A command for a return to the second, third or fourth reference position is error. (The address P command is in error.) Although an option for a return to the third or fourth reference position was not set, 3 or 4 was specified in address P.

Applies to
Fanuc CNC Controls

  • 21 Model B
  • 30i, 31i, 32i Model A
Fanuc Alarm 46 ILLEGAL REFERENCE RETURN COMMAND