Fanuc Alarm 5440 ILLEGAL DRILLING AXIS SELECTED


Fanuc Alarm 5440 ILLEGAL DRILLING AXIS SELECTED (M series)

Fanuc Alarm Description
The drilling axis specified for the drilling canned cycle is incorrect. The G code command block of the canned cycle does not specify the Z point of the drilling axis. When there is a parallel axis with the drilling axis, the parallel axis is also specified at the same time.