Alarm: 235 SPINDLE Z FAULT
Haas Alarm Description:
Encoder marker pulse count failure. This alarm usually indicates that the encoder mounted on the spindle has been damaged and encoder position data is unreliable. Loose encoder connectors at P1-P4 can also cause this.
References