Haas Alarm: 536 COMMAND FOUND ON DPRNT LINE


Alarm: 536 COMMAND FOUND ON DPRNT LINE

Haas Alarm Description:
A G-code was included on a DPRNT block. Make two separate blocks, only DPRNT statement on block allowed. Check macro formatting.

References

  1. Haas Alarms PDF by Haas Automation, Inc.