Haas Alarm: 642 642 APC-PIN CLEAR SWITCH FAULT – Haas Mill


Alarm: 642 642 APC-PIN CLEAR SWITCH FAULT – Haas Mill

Haas Alarm Description:
One of the pallet changer pin clear switches was contacted unexpectedly. The most likely cause is debris on a switch. Also check the pin clear switches for damage and their electrical wiring for damage. After correcting the condition, run M50 to continue machining.

References

  1. Haas Alarms PDF by Haas Automation, Inc.
Haas Alarm: 642 642 APC-PIN CLEAR SWITCH FAULT – Haas Mill