Haas Parameter 295 SHTL SETTLE TIME – Haas Mill
Used on mills with an air driven shuttle. Allows settling time for the shuttle after it has moved toward the spindle and before a tool change is performed. It should be set to approximately half a second (500) on all mills with the air driven shuttle. This may vary. All other mills can be set to 0, since they are unaffected.
Haas Parameter 295 SHTL SETTLE TIME – Haas Mill