Haas Setting 69 DPRNT Leading Spaces


Haas Setting 69 DPRNT Leading Spaces

Haas Setting Description
This is an On/Off setting. When set to OFF the control will not use leading spaces generated by a macro DPRNT format statement. Conversely when set to ON the control will use leading spaces The following example illustrates control behavior when this setting is OFF or ON.

#1= 3.0;OUTPUT
0 G90 X#1;OFFON
PRNT[X#1[44]];X3.0000X 3.0000

Notice the space between the “X” and the 3 when the setting is ON. Information can be easier to read when this setting is ON.

References

  1. Haas Lathe Operator’s Manual by Haas Automation, Inc.
  2. Haas Mill Operator’s Manual by Haas Automation, Inc.
Haas Setting 69 DPRNT Leading Spaces