Okuma Alarm-A 1278 Laser measurement data NG


Okuma Alarm-A 1278 Laser measurement data NG
Inductosyn pitch error between the encoder read data and the laser measurement data does not satisfy the following:
In the X-axis:-0.0254mm – +0.0254mm
In the Z-axis:-0.0127mm – +0.0127mm

Code
Hexadecimal number of the difference between the encoder read data and the laser measurement data

Probable Faulty Locations
1)Position encoder
2)Inductosyn
3)Setting of Inductosyn coupling compensation amount
Program Example:
G0 X1000
LMW X0
:

Okuma Alarm-A 1278 Laser measurement data NG