Okuma Alarm-A 1279 IND. CMP. data verification failure


Okuma Alarm-A 1279 IND. CMP. data verification failure
The difference between the designated inductosyn pitch error compensation data and the read pitch error compensation data does not satisfy the following:
In X-axis:-0.006mm – +0.006mm
In Z-axis:-0.003mm – +0.003mm

Code
Hexadecimal number of the difference between the designated pitch error compensation data and the read pitch error compensation data.

Probable Faulty Locations
1)Position encoder
2)Inductosyn
3)Setting of Inductosyn coupling compensation amount
Program Example:
G0 X1000
LMV X0
:

Okuma Alarm-A 1279 IND. CMP. data verification failure