Okuma Alarm-A 1283 C-axis command not possible
C-axis movement command is designated while it is not acceptable.
Object
SYSTEM
Code
1->C-axis is not connected.
2->C-axis is not unclamped.
Probable Faulty Locations
1)Program error
2)Operation error
Program Example:
N100 M109 C-axis disconnection N101 G00 X100 C100 C-axis rapid feed to 100-deg position
Operation Example:
C-axis movement command is designated while C-axis is not clamped.