Okuma Alarm-A 1426 Moved inside barrier area


Okuma Alarm-A 1426 Moved inside barrier area
Axis entered into a barrier area.

Code
1->Concerning MacTurn30, axis entered into a barrier area by axis movement of X-Y plane in Y-axis mode(in G138 command).
3->In the spec of Sub-Spindle Unit Barria, axis move to the barrier area. The interference range is set by the next screen
“OPTIONAL PARAMETER Y-axis BARRIER” (NO.4-6)

Probable Faulty Locations
1) Barrier area boundary is located on a point that added barrier length set data added minus stroke end limit position data.

Axis entered into a barrier area beyond boundary.
By manual jog feed, please move axis out from a barrier area.

Barrier length set data
X-axis: optional parameter long word No.66(It is Radius)
Y-axis: optional parameter long word No.67
Z-axis: optional parameter long word No.68

Okuma Alarm-A 1426 Moved inside barrier area