Okuma Alarm-A 1469 APA speed XS-axis
Actual position velocity of Xs-axis exceeds 15 m/min.
Index
None
Character-string
None
Code
Hexadecimal of APA velocity(unit:0.2 um/s)
Probable Faulty Locations
Faulty position encoder.
The command given in the synchronization mode is too large.
Measures to Take
Check the position encoder.
Review the cutting condition such as cam profit and spindle speed.