Okuma Alarm-A 1477 Syncronous mode command


Okuma Alarm-A 1477 Syncronous mode command
The synchronous mode operation command is designated while spindle rotation command has not been designated.
The synchronous operation start command is designated in the MDI mode.

Index
None

Character-string
None

Code
1->The synchronous mode operation command is designated while spindle rotation command has not been designated.
2->The synchronous operation start command is designated in the MDI mode.
4->The different synchronous operation start command was executed while synchronously operation.
5->The synchronous operation start command was executed though the cam processing data is a unforwarding.
6->The synchronous operation start command was executed while controlling the spindle speed variation.
7->The spindle speed variation control command was executed while synchronously operation.

Probable Faulty Locations
1->Program error
2->Operator’s error

Measures to Take
Review the program.