Okuma Alarm-A 1728 C-axis clamp/unclamp command not possible


Okuma Alarm-A 1728 C-axis clamp/unclamp command not possible
C-axis clamp/unclamp (M147/M146) command is designated when the C-axis is not connected.
C-axis clamp/unclamp command is given to C-axis under the control of the other turret.

Object
SYSTEM

Code
1->C-axis clamp/unclamp command is designated when the C-axis is not connected.
2->C-axis clamp/unclamp command is given to C-axis under the control of the other turret.

Probable Faulty Locations
1)Program error
2)Operation error
Program Example:
M109 C-axis disconnected
M147 C-axis clamp
Operation Example:
M146/M147 is designated in the MDI mode when the C-axis is not connected.

Okuma Alarm-A 1728 C-axis clamp/unclamp command not possible