Okuma Alarm-A 1739 Chuck clamp pressure insufficient


Okuma Alarm-A 1739 Chuck clamp pressure insufficient
During a chuck open/close operation, ID/OD gripping direction is changed. Or low chucking pressure state has continued for more than 2[s].

Object
SYSTEM

Code
100->Low chucking pressure state has continued for 2[s].
Spindle-1:I/O check NO.24 INPUT bit 4 (iCPA/) is 0.

In the case of air chuck, I/O check NO.38 INPUT bit B (iAPA/) is 0.

Spindle-2:I/O check NO.32 INPUT bit 5 (i2CPA/) is 0.

In the case of air chuck, I/O check NO.38 INPUT bit F (i2APA/) is 0.

101->Rear low chucking pressure state has continued for 2[s].
102->Low Tailstock chucking pressure state has continued for 2[s].

I/O check NO.56 INPUT bit 3 (iTSCPA/) is 0.

103->Low face driver moving pressure state has continued for 2[s].
104->The front air chuck pressure has dropped during spindle rotation.
105->The rear air chuck pressure has dropped during spindle rotation.

Probable Faulty Locations
1)Low hydraulic oil level
2)Defective hydraulic oil motor