Okuma Alarm-A 1750 Tailstock interference


Okuma Alarm-A 1750 Tailstock interference
The tow-along type automatic rest and the tailstock interfered each other, or G152 (tailstock movement by program) is designated while the tow-along type automatic rest is connected to the saddle.

Code
1->Interference between the tow-along type automatic rest and the tailstock
2->G152 is designated while the tow-along type automatic rest is being connected to the saddle.

Probable Faulty Locations
1)Program error
2)Operation error
Program Example:
:
M79 Automatic rest close
G152 Z100
:

Okuma Alarm-A 1750 Tailstock interference