Okuma Alarm-A 1837 Worktable overload
The work table overload sensor was activated and the ‘Interlock/(Workpiece Push limit switch)’ signal turned OFF.
Measures to Take
1) Reset the alarm and manually move the spindle to the positive direction along the Z axis.