Okuma Alarm-A 1876 Swing interlock


Okuma Alarm-A 1876 Swing interlock

Code
None->They went along a swing order by the condition that there is loader Z axis in a position of swing action badness.
Swing action possibility scope of Z axis is the scope which had set on loader parameter NO.12 – NO.15.
1->A swing command (M308/M309) was issued in the NC lathe.
2->A swing command (M308) was issued in the interference position.
3->The Y-axis movement command to the interference position was issued with not the M309 swing conditions.
10->A hand swing command was issued with the loader hand B position area.
11->A swing command (M309) was issued in the swing/machine interference position. Or, the loader-axis movement command to the swing/machine interference position was issued with not the M308 swing conditions.
12->They went along a swing order by the condition that there is loader Y axis in a position of swing action badness.

Object
3->Z axis

Probable Faulty Locations
1)Programming error
2)Operation error

Okuma Alarm-A 1876 Swing interlock