Okuma Alarm-A 8590 Tailstock pedestal condition


Okuma Alarm-A 8590 Tailstock pedestal condition

Code
1->M355 or M356 command is designated while the spindle is not in the stopped state (zero rotation input ON, spindle rotation command (M03/M04) not active, spindle rotating signal not ON).

The tailstock pedestal is not at the specified position when the spindle rotation command (M03/M04) is designated.

2->Tailstock pedestal is unclamped while the spindle is not in the stopped state (zero rotation input ON, spindle rotation command (M03/M04) not active, spindle rotating signal not ON).

The tailstock pedestal is not clamp status when the spindle rotation command (M03/M04) is designated.

3->M355 or M356 command is designated while the machine is not set for the center work.

Okuma Alarm-A 8590 Tailstock pedestal condition