Okuma Alarm-B 2060 Fan motor error on panel computer unit
The rotational speed of the cooling fan motor on panel computer unit is out of the regular range.
Object
None
Character-string
None
Code
Fan motor identifier
10101->CPU
Probable Faulty Locations
The cooling fan motor of panel computer unit
Measures to Take
Please turn off the power supply of the operation panel. Please change the cooling fan motor.