Okuma Alarm-B 2196 MCS Full abso scale link error
An alarm occurred in full absolute scale communication.
Object
AXIS or none (spindle)
Character-string
None
Code
XXYYZZZZ
XX=FF Fixed
YY=00 Fixed
ZZZZ= E-link error status at the time of error detection.
Each bit shows the kind communication error.
bit15 1: Communication error generated by independent encoder
bit14 1: Communication error generated by ABSOSCALE 2
bit13 1: Communication error generated by ABSOSCALE or axis-mount encoder.
bit12 1: Communication error generated by monitor encoder
bit11 Not defined
bit10 1:AT mode transmission loop error
bit9 1:Excessive number of data counts at the receiving interface
bit8 Not defined
bit7 Not defined
bit6 1: Modulation code error
bit5 1: CRC error
bit4 1: Format error
bit3 1: Double transmission error
bit2 1: Double reception error
bit1 1: Parity error
bit0 1: Time-out error
bit15 1: Communication error generated by independent encoder
bit14 1: Communication error generated by ABSOSCALE 2
bit13 1: Communication error generated by ABSOSCALE or axis-mount encoder.
bit12 1: Communication error generated by monitor encoder
bit11 Not defined
bit10 1:AT mode transmission loop error
bit9 1:Excessive number of data counts at the receiving interface
bit8 Not defined
bit7 Not defined
bit6 1: Modulation code error
bit5 1: CRC error
bit4 1: Format error
bit3 1: Double transmission error
bit2 1: Double reception error
bit1 1: Parity error
bit0 1: Time-out error
Probable Faulty Locations
– Full ABSOSCALE
– Encoder link cable or connector
– Inverter unit control board