Okuma Alarm-B 2214 Subscript left side incorrect


Okuma Alarm-B 2214 Subscript left side incorrect
The subscript expression is incorrect.
Numerical value of the subscript expression of the system variable is too large or too small.
Tool offset and tool nose radius compensation
1 through 32 (1 through 64 for 64-pair specification)
Tool interference
1 through 12
Two subscript expressions are designated by system variable and I/O variable.
Subscript expression: [*] in such a variable as V***[*]

Object
SYSTEM

Code
2->Two subscript expressions using I/O variable
None->Two subscript expressions using system variable
Others->Hexadecimal number of the programmed subscription expressions

Probable Faulty Locations
Subscript expression
Program Example:
VTOFX [34] = 10 — [Code]22 (Hexadecimal of 34)

^^Designate 1- 32.

VNSRZ [-1] = 5 —- [Code]FFFFFFFF (Hexadecimal of -1)

^^Designate 1- 32.

V1 = VDIN [1,2][Code]2

^^^Do not designate two subscript expressions.

VDOUT [1,2] = 20 — No code

^^^Do not designate two subscript expressions.