Okuma Alarm-B 2247 No S command
The G96 or G97 sequence has no S command.
G96: Constant speed cutting ON
G97: Cancel of G96
Object
SYSTEM
Character-string:Coordinate systemG140, G141, G142
Code
1
Probable Faulty Locations
G96, G97
Program Example:
N010 G96
Measures to Take
Designate an S command.
Example:
N010 G96 S100 : N200 G97 S500Okuma Alarm-B 2247 No S command