Okuma Alarm-B 2256 Mistake in D command
Illegal D command
In a gauging cycle, D value is not within a range of 0 and 99999.999.
Or with cam turning specification models, when setting value for D (major axis of an oval) and L (lift amount of an oval) in the
shape definition file (LSF), the D command value is not proper.
Object
SYSTEM
Code
Hexadecimal number of designated D command
Probable Faulty Locations
D command
Program Example:
G30 Z50 D-10 L10
Measures to Take
Change D command; 0<=D<=99999.999.Example:
G30 Z50 D10 L10
Check the D command value.
Related Specifications
1)In-process gauging
2)Cam turning specification