Okuma Alarm-B 2259 Mistake in SB command


Okuma Alarm-B 2259 Mistake in SB command
Designated SB command is not: 0<=SB<=60000SB command is designated for B-turret.Object
SYSTEM

Code
1->SB command is designated for B-turret.
Others->Hexadecimal number of commanded SB value

Probable Faulty Locations
Program error
Program Example:

N010 M13 SB=65000

Measures to Take
Check the SB command; check whether the SB command is designated at the B-turret side.
In the example program above, the SB command value is greater than 60000; correct the program.

N010 M13 SB=60000
Okuma Alarm-B 2259 Mistake in SB command