Okuma Alarm-B 2260 Mistake in QA command


Okuma Alarm-B 2260 Mistake in QA command
QA command(the number of C-axis revolutions for positioning) is designated for B-turret.
QA command is designated in other than the G00 and G01 mode.
Programmed QA value is not:0<=QA<=1999Object
SYSTEM

Code
1->QA command is designated for B-turret.
2->QA command is designated in other than G00 and G01 mode.
4->QA command is designated in G121 mode.
Others->Hexadecimal number of QA value

Probable Faulty Locations
Faulty program (block including QA command)
Program Example:

G01 X100 QA=2000

Measures to Take
Check the QA command.

G01 X110 QA=1900

[Related Specifications]
Multi-machining model

Okuma Alarm-B 2260 Mistake in QA command