Okuma Alarm-B 2282 SCHEDULE PROGRAM ‘Q’


Okuma Alarm-B 2282 SCHEDULE PROGRAM ‘Q’
The schedule program includes an improper Q command (the number of repetitions).

Code
1->Data other than address character is designated where Q command must be designated.
4->Address character other than Q is designated where Q command must be designated.
Others->Numerical value of Q is not 0Probable Faulty Locations
Schedule program
Program Example:
PSELECT A.MIN ,, 20 –[Code]1
PSELECT B.MIN ,, P 10 –[Code]4
PSELECT C.MIN ,, Q 20000 –[Code]D020(Hexadecimal of 20000)

Measures to Take
Correct the Q command in the schedule program.
Example: PSELECT A.MIN ,, Q 20

Okuma Alarm-B 2282 SCHEDULE PROGRAM ‘Q’