Okuma Alarm-B 2347 ROBOT no spec.


Okuma Alarm-B 2347 ROBOT no spec.
G227 (robot request command) is designated although the control has no robot specification.

Probable Faulty Locations
Program error
Program Example:ROBOT O100

Measures to Take
Delete the ROBOT instruction from the program.

Okuma Alarm-B 2347 ROBOT no spec.