Okuma Alarm-B 2353 CHAMFERING G01 mode
Chamfering commands are designated in other than G01 mode.
Object
SYSTEM
Code
None->No G code programmed
2->G02
3->G03
1F->G31
20->G32
21->G33
22->G34
23->G35
FE->G00
Probable Faulty Locations
Program error
Program Example:
N009 G00 X50 Z100 N010 G75 X100 L-5 F0.5 N011 Z50
Measures to Take
Check the G codes designated in the G75 block.
For the example program, add an G01 command to the program.
N010 G75 G01 X100 L-5 F0.5Okuma Alarm-B 2353 CHAMFERING G01 mode