Okuma Alarm-B 2357 CHAMFERING Any angle calculation


Okuma Alarm-B 2357 CHAMFERING Any angle calculation
Calculation error during the calculation of automatic chamfering with an arbitrary angle.

Object
SYSTEM

Code
XYY
YY:
bit0->Overflow in converting into integer
bit1->Exponential underflow
bit2->Exponential overflow
bit3->Calculation of root of a negative number
bit4->Division by 0
bit5->Angle overflow for SIN, COS, TAN and COT
X:
1->Calculation of the starting point of chamfering
2->Calculation of the end point of chamfering
3->Calculation of the center of the arc for rounding
4->Calculation of the starting and end points for rounding
5->Calculation for obtaining the chamfering direction

Probable Faulty Locations
Program error

Measures to Take
Check the contents of error in the program from the alarm code number; remove the cause which intervenes the execution of arbitrary angle chamfering command.

Related Specifications
Automatic any-angle chamfering

Okuma Alarm-B 2357 CHAMFERING Any angle calculation