Okuma Alarm-B 2388 LAP No G-code


Okuma Alarm-B 2388 LAP No G-code
No G80 command up to the end of the program after G81 or G82 is designated. G81 or G82 is not designated in the sequence
assigned with the sequence name designated in the sequence containing G85 or G86.
G80: Ends shape definition.
G81: Starts longitudinal shape definition.
G82: Starts end face shape designation.
G85: Calls rough bar turning cycle.
G86: Calls rough copy turning cycle.

Object
SYSTEM

Code
1->No G80 designated
2->G81 or G82 is not designated in the sequence assigned with the sequence name designated in the sequence containing
G85 or G86.

Probable Faulty Locations
Program error
Program Example:

NLAP1
:
N010 C80
N011 G85 NLAP1

Measures to Take
Check the G81, G82 and G83 commands.
In the example program above, G81 or G82 command is not designated in the NLAP1 sequence; designate G81 or G82 command.
NLAP1 G81

Okuma Alarm-B 2388 LAP No G-code