Okuma Alarm-B 2389 LAP NOSE-R comp. cancel


Okuma Alarm-B 2389 LAP NOSE-R comp. cancel
Nose radius compensation mode is not canceled at the end of LAP (sequence containing G80).
G80: Ends shape definition.

Object
SYSTEM

Probable Faulty Locations
Program error
Program Example:

NLAP1 G81
:
N010 G41 G00 X-- Z--
:No G40 command designated within these blocks
N020 G80

Measures to Take
Check the G41, G42 and G40 commands in LAP program.
In the example program above, it is necessary to cancel the nose R compensation mode before the G80 command is designated.

N010 G41 G00 X-- Z--
:
N019 G40 X-- Z--
N020 G80