Okuma Alarm-B 2412 TOOL LIFE CONTROL no T-entry
Tools are not registered in the designated tool group.
Object
SYSTEM
Code
FFFFFFFF
Probable Faulty Locations
Faulty program or setting error of tool life management data and/or tool group data
Operation Example:N010 TG = 1
Measures to Take
Check the TG command and the information in the tool life management group information.