Okuma Alarm-B 2412 TOOL LIFE CONTROL no T-entry


Okuma Alarm-B 2412 TOOL LIFE CONTROL no T-entry
Tools are not registered in the designated tool group.

Object
SYSTEM

Code
FFFFFFFF

Probable Faulty Locations
Faulty program or setting error of tool life management data and/or tool group data
Operation Example:N010 TG = 1

Measures to Take
Check the TG command and the information in the tool life management group information.
In the example above, registration is made so that tool group number 1 is not used; correct the program or setting of the tool group information.

Okuma Alarm-B 2412 TOOL LIFE CONTROL no T-entry