Okuma Alarm-B 2435 ATC MT
A wrong tool number or turret number was specified with the MT command.
MT: Tool preparation command
(MT = $$##,
where $$ is the tool No. and
## is the turret No. )
In the spec of “H1 Turret”, MT command expect for “MT=1” can not be executed.
In the case of “TOOL OFFSET 999” spec and “MULTI EDGE TOOL” spec, tool number were not the following ranges.
MULTI-TOOL 8-EDGES:1-210 or 281-999
MULTI-TOOL 12-EDGES:1-210 or 321-999
Code
XXXYY
XXX:Tool number
YY :Turret number