Okuma Alarm-B 2475 W-axis command G-code
The G code (G122 or G123) designating on which side, A or B, the W-axis command should be given is designated for other than sub-spindle specification models.
Concerning Sub spindle-tailstock Control specification, it instructed with the instruction prohibited.
Object
SYSTEM
Code
Hexadecimal number of the designated G code
Probable Faulty Locations
Program error
Program Example:
G13 G14 G123 G123 : G0 W100 : :
Measures to Take
Delete G122 or G123 from the program.