Okuma Alarm-B 2518 Synchronized tapping command
There is error in a synchronization tap instruction.
Object
SYSTEM
Code
X
1->There is not a synchronization tap specification.
2->It was not C axis connection state at the time of a M tool spindle synchronization tap instruction.
3->It was C axis connection state at the time of a Main spindle synchronization tap instruction.
4->It is already in Main spindle synchronized tapping command by other Turret at the time of Main spindle synchronized tapping command.
Probable Faulty Locations
Programming error
Measures to Take
1)A synchronization tap instruction is deleted from a program.
2)They are C axis connection states.