Okuma Alarm-B 2520 Mistake in TP command


Okuma Alarm-B 2520 Mistake in TP command
TP command is wrong.

Object
SYSTEM

Code
1->When B axis control specification was not selection, it did TP command. Or it did TP command on the B turret.
2->TP command had singly instructed.
3->Value of TP command had instructed a value except for 0 or 1

Probable Faulty Locations
Program error

Measures to Take
1)When B axis control specification is not selection, TP command on the B turret does not do it.
2)TP command instructs by ‘T+TP’.
3)It turns an instruction value of TP command into 0 or 1 .
Or, it modifies an instruction value of TP command on an appropriate value.

Okuma Alarm-B 2520 Mistake in TP command