Okuma Alarm-B 2525 Chuck coordinate change condition


Okuma Alarm-B 2525 Chuck coordinate change condition
In the spec of ACC:
Coordinates cannot be selected.

Object
SYSTEM

Code
1-> Coordinate instruction (G124/G125) was executed while Constant Surface mode.
2-> Coordinate instruction (G124/G125) was executed while Nose-R Compensation mode.

Measures to Take
The program instruction is defective.