Okuma Alarm-B 2525 Chuck coordinate change condition
In the spec of ACC:
Coordinates cannot be selected.
Object
SYSTEM
Code
1-> Coordinate instruction (G124/G125) was executed while Constant Surface mode.
2-> Coordinate instruction (G124/G125) was executed while Nose-R Compensation mode.
Measures to Take
The program instruction is defective.