Okuma Alarm-B 2529 Thermal deviation compensation
Thermal deviation compensation is impossible since the temperature data sent via the TMP board is abnormal, or the total deviation amount exceeded the allowable maximum total deviation amount of the corresponding axis.
Index
None
Character-string
Only in case of code=2,3
AAAA : It is VPE at the alarm.
BBBB : It is VPE of the first time.
VPE at the alarm is -99.9um.
VPE of the first time is -600.0um.
Case of VPE[7]- VPE[18]:
AAAA,BBBB: It is VPE at the alarm.
(Case of VPE[17]- VPE[18]: VPE[17],VPE[18])
Case of VPE[17]- VPE[18]:
VPE[18] at the alarm is -600.0um.
Code
X=1 ->Abnormal temperature data, input from the TMP board
Y=Thermistor channel number
X=2 ->Case of VPE[1]- VPE[6]
The absolute value of “Expansion/shrinkage” displayed in the correction monitor exceeded the allowable maximum total deviation amount 2.
YY=VPE number(VPE[9]- VPE [10]:Hexadecimal number display of “9” of VPE[9])
Probable Faulty Locations
1) Defective TMP board or defective thermistor
2) Abnormal parameter data