Okuma Alarm-B 2548 X-, Z-axis synchronized feed mode
It performed X-Z both axis synchronaized feed mode command by the condition that a receipt valid condition has not formed.
Or, it performed prohibited command in X-Z both axis synchronaized feed modes.
Object
SYSTEM
Code
1->It performed M300/M303 commands by the end of in a nose-R mode or LAP cycle.
2->M300/M303 commands which is performed on the side of A side and B do not coincide.
3->When there was another side on a synchronous waiting condition by a receipt of M02 commands, it performed M300/M303 commands. Or, when there was another side on a synchronous waiting condition by a receipt of M300/M303 commands, it performed M02 commands.
4->When there was another side on a synchronous waiting by a receipt of G140/G141 commands, it performed M300/M303 commands. Or, when there was another side on a synchronous waiting condition by a receipt of M300/M303 commands, it performed G140/G141 commands.
5->When there was another side on a synchronous waiting condition by a receipt of M100 commands, it performed M300/M303 commands. Or, when there was another side on a synchronous waiting condition by a receipt of M300/M303 commands, it performed M100 commands.
6->Concerning a sequent return, when there was on the condition which another side has realized on a return block, it performed M300/M303 commands. Or, when there is another side on a synchronous waiting condition by a receipt of M300/M303 commands, it has reached a return block of sequent return.
7->When there was on the condition that the spindle mode which a mutual saddle is choosing does not coincide, it performed M300/M303 commands.
8->In X-Z both axis synchronaized feed modes, command of X-Z both axis synchronaized feed mode invalidity (: M300) exceptions was performed on the side of B.
9->In X-Z both axis synchronaized feed modes, command of the following either was performed.
10->It performed M303 commands by the condition that there is B side on C axis controlled mode.
11->Movement command of axis was performed by M300/M303 commands and an identical block.
Probable Faulty Locations
Programming error
Measures to Take
It amends programming error.