Okuma Alarm-B 2580 Mistake in XS command
Illegal Xs-axis(cam-axis) positioning command (asynchronous mode command).
Index
None
Character-string
None
Code
1->Xs-axis rapid positioning command is designated in the synchronous mode.
2->Xs-axis rapid positioning command is designated in other than the G00 mode.
3->Xs-axis rapid positioning is executed in the develop mode.
Hexadecimal of positioning command value that exceeded the allowable input range.
Probable Faulty Locations
Operator’s error
Measures to Take
Review the machine condition in which the Xs-axis rapid
positioning command is designated as well as designated
positioning command.