Okuma Alarm-B 2618 Workpiece detection sensor not ready


Okuma Alarm-B 2618 Workpiece detection sensor not ready

Code
1->The work-piece detection sensor is not indexed, or the turret station set at the parameter as the station having a work detection sensor differs from the currently indexed station.

Under the above condition, the system variable (VWKME) was issued to specify the measurement direction.

2->The work-piece detection sensor is indexed but the system variable (VWKME) for specifying the measurement direction is not issued.

The measurement command (G30) was issued under such condition.
Okuma Alarm-B 2618 Workpiece detection sensor not ready