Okuma Alarm-B 2630 Mistake in SC command


Okuma Alarm-B 2630 Mistake in SC command
Illegal SC command
Numerical value of SC command is not: 0<=SC<=9999Object
SYSTEM

Code
Hexadecimal number of programmed SC command
Hexadecimal number of programmed SC command :

SC instruction is not 0<=SC<=9999.

Probable Faulty Locations
(1)SC command
Program Example:

N010 G00 X500 Z500 M42 SC10000 T0101

Measures to Take
(1)Change SC command value so that it is within the allowable range.

Okuma Alarm-B 2630 Mistake in SC command