Okuma Alarm-B 2667 X-axis mirror image coordinates selected


Okuma Alarm-B 2667 X-axis mirror image coordinates selected
The axis movement instruction was executed in AUTO mode, while X-axis mirror image coordinate system was selected.
Otherwise, C-axis connection instruction or Y-axis mode instruction was executed in AUTO mode, while X-axis mirror image coordinate system was selected.

Code
1-> The axis movement instruction was executed in AUTO mode before the G105 instruction was done, while X-axis mirror image coordinate system was selected.
2-> C-axis connection instruction was executed on X-axis mirror image coordinate system.

Probable Faulty Locations
The program instruction is defective.

Measures to Take
It starts in X-axis mirror image coordinate system OFF mode.
Otherwise, X-axis mirror image coordinate OFF instruction G104 is executed, before the axis movement instruction was done in AUTO mode.

Okuma Alarm-B 2667 X-axis mirror image coordinates selected