Okuma Alarm-C 3192 MCS Motor overload


Okuma Alarm-C 3192 MCS Motor overload
The motor load has exceeded the preset value, activating the overload protection function.

Object
Axis name or none (spindle)

Character-string
None

Code
YYYYZZZZ
YYYY-> Gamma of the protection curve used to detect overload
ZZZZ-> Internally calculated overload data

Probable Faulty Locations
– Motor
– Overload caused by machine operation
– Servo data file

Okuma Alarm-C 3192 MCS Motor overload