Okuma Alarm-C 3248 Size catcher Data NG


Okuma Alarm-C 3248 Size catcher Data NG
A faulty data was sent from the measuring device.

Code
1->In automatic operation (including manual interruption), the offset value sent from the size catcher exceeded the set value at the parameter.
2->The tool offset group number or the tool offset number corresponding to the point number designated by the size catcher is 0.
3->The difference between the previous offset value and the offset value sent from the size catcher this time exceeds the value set at the parameter.

Parameter
OPTIONAL PARAMETER (OTHER FUNCTION)
Tool offset,Nose-R limit value for addition

Okuma Alarm-C 3248 Size catcher Data NG