Okuma Alarm-C 3250 Size catcher Unable to transmit


Okuma Alarm-C 3250 Size catcher Unable to transmit
An error occurred in the transmission circuit during gauging data communication.

Character-string
CN? (RS-232C channel causing the alarm)

Code
XYYYY (YYYY is effective only when X is 6.)
X:
1->The communication tank is being initialized.
2->An RS-232C channel number is wrong.
3->The requested channel is not provided.
4->The identification message address is wrong.
5->The channel is being used for the other job.
6->Transmission error (with details)
YYYY:
bit 0->A ready error occurred. (DSR was not ON.)
bit 1->The RS-232C device was not open for transmission.
bit 2->Data could not be written in the transmission buffer within the specified time.
bit 3->Transmission was ended by forced termination.
Message:CN? (RS-232C channel causing the alarm)

Probable Faulty Locations
1)Baud rate set at the parameter

OPTIONAL PARAMETER (RS232C)

2)OPTIONAL PARAMETER (RS232C)
3)FRP board, RPP board
4)Communication cable