Okuma Alarm-C 3253 Size catcher Data format error


Okuma Alarm-C 3253 Size catcher Data format error
The data which did not correspond to the data format was received.

Code
1->The number of receive record exceeded 12.
2->A numerical data outside the range was received.
3->The data format does not agree the format type designated by the parameter bit data.
4->Inappropriate character data was received.
5->The number of the digits of the measuring data received exceeded the allowable digit number.
6->Two or more decimal points were present in the measuring data received.
7->The unit system used by the NC and the unit system used in the transmission data do not agree.

Probable Faulty Locations
1)OPTIONAL PARAMETER (RS232C)
2)Size catcher unit

Okuma Alarm-C 3253 Size catcher Data format error