Okuma Alarm-C 3699 MCS Linear scale 1 error


Okuma Alarm-C 3699 MCS Linear scale 1 error
Illegal data was detected in Liner scale 1(MITUTOYO).

Object
Axis

Character-string
None

Code
XXYYZZZZ
XX= Liner scale 1 status

bit7: alarm
bit6: communication error
bit2: communication error(every detection)
bit0: alarm code distinction bit

(bit0=1: An alarm occurred in MITUTOYO scale.)

YY=Liner scale 1

case of XX=88

bit7: over speed
bit6: communication error
bit5: EEPROM error
bit4: CPU error
bit3: electric capacity error
bit2: photo electron error
bit1: digit match error
bit0: initialize error

case of XX=80

43: MITUTOYO scale no response
44: MITUTOYO scale ID error

case of XX=C0

00-3F: Gateway receive error
46: REQ time over error

ZZZZ= Liner scale 1 position data

position data of every 2mm pitch

Probable Faulty Locations
Linear scale 1

Corrective Action
Change Linear scale 1

Okuma Alarm-C 3699 MCS Linear scale 1 error